7.4
Setpoint values for monitoring the bearing temperature
Prior to commissioning
If the machine is equipped with bearing thermometers, set the temperature value for
disconnection on the monitoring equipment before the first machine run.
Table 7-1
Set values for monitoring the bearing temperatures before commissioning
Set value
Temperature
Disconnecting during commissioning
120 °C
Normal operation
Measure the normal operating temperature T
op
at the installation site in °C. Set the values for
disconnection and warning according to operating temperature T
op
.
Table 7-2
Set values for monitoring the bearing temperatures in normal operation
Set value
Temperature
Warning in normal operation
T
op
+ 5 K
Disconnection in normal operation
T
op
+ 10 K
7.5
Set values for monitoring the winding temperature
Prior to commissioning
Before running the machine for the first time, set the temperature value for shutdown on the
monitoring device.
Table 7-3
Set values for monitoring the winding temperatures during commissioning
Set value
Temperature
Shutdown
145 °C
Normal operation
Measure the normal operating temperature T
operation
at the installation site in °C. Set the values
for shutdown and warning according to the operating temperature T
operation
.
Table 7-4
Set values for monitoring the winding temperatures in normal operation
Set value
Insulation class 155(F)
Warning
T
op
+ 10 K ≤ 145 °C
Shutdown
T
op
+ 15 K ≤ 155 °C
Start-up
7.5 Set values for monitoring the winding temperature
SIMOTICS TN Series N-compact 1LA8
86
Operating Instructions 05/2014
Содержание 1LA8
Страница 2: ...23 05 2014 10 18 V8 00 ...
Страница 12: ...Table of contents SIMOTICS TN Series N compact 1LA8 12 Operating Instructions 05 2014 ...
Страница 14: ...Introduction 1 1 About these instructions SIMOTICS TN Series N compact 1LA8 14 Operating Instructions 05 2014 ...
Страница 60: ...Assembly 5 3 Installing the machine SIMOTICS TN Series N compact 1LA8 60 Operating Instructions 05 2014 ...
Страница 88: ...Start up 7 7 De energizing SIMOTICS TN Series N compact 1LA8 88 Operating Instructions 05 2014 ...
Страница 100: ...Operation 8 11 faults SIMOTICS TN Series N compact 1LA8 100 Operating Instructions 05 2014 ...
Страница 173: ...AC Declaration of conformity 1LA8 area 22 AA KE NSR _1LA8_1PQ8_1PP8_1LP8 ...