4. When positioning the machine, ensure that a uniform axial gap (y→0) is maintained around
the coupling.
5. Fix the machine to the foundation. The choice of fixing elements depends on the foundation
and is the plant operator's responsibility.
'
[
\
①
Plates placed under the motor for alignment
②
Laser alignment
Figure 5-3
Schematic diagram: Aligning the machine to the driven machine
Table 5-2
Permissible deviations for aligning the machine with flexible coupling
Max. speed n
max
Max. parallel offset x
Max. angular offset y
n
max
≤ 1500 rpm
x
max
= 0.08 mm
y
max
= 0.08 mm / 100 mm ∅ D
1500 rpm <
n
max
≤ 3600 rpm
x
max
= 0.05 mm
y
max
= 0.05 mm / 100 mm ∅ D
Note
Machine expansion
When performing alignment, make allowance for the thermal expansion of the machine due
to rising temperature.
Assembly
5.3 Installing the machine
SIMOTICS TN Series N-compact 1LA8
Operating Instructions 05/2014
57
Содержание 1LA8
Страница 2: ...23 05 2014 10 18 V8 00 ...
Страница 12: ...Table of contents SIMOTICS TN Series N compact 1LA8 12 Operating Instructions 05 2014 ...
Страница 14: ...Introduction 1 1 About these instructions SIMOTICS TN Series N compact 1LA8 14 Operating Instructions 05 2014 ...
Страница 60: ...Assembly 5 3 Installing the machine SIMOTICS TN Series N compact 1LA8 60 Operating Instructions 05 2014 ...
Страница 88: ...Start up 7 7 De energizing SIMOTICS TN Series N compact 1LA8 88 Operating Instructions 05 2014 ...
Страница 100: ...Operation 8 11 faults SIMOTICS TN Series N compact 1LA8 100 Operating Instructions 05 2014 ...
Страница 173: ...AC Declaration of conformity 1LA8 area 22 AA KE NSR _1LA8_1PQ8_1PP8_1LP8 ...