Index
Function
WLL180T
KTL180
OD1 / AO
D1
OL1 / AOD
1
AOD1
Acc-
ess
Data type
Content/meaning
148
Barycenter
-
-
x
-
-
rw
UInt 16
0: Max. light
1: Next point
2: 2nd point
3: 3rd point
4: 4th point
5: 5th point
151
Hysteresis
-
-
x
-
-
rw
UInt 16
OD1 15 mm: 0 … 7,499 (default: 50)
OD1 35 mm: 0 … 2,249 (default: 50)
OD1 100 mm: 0 … 7,499 (default: 50)
152
Sensitivity
-
-
x
-
-
rw
UInt 16
0: Auto adjustment
1: Minimal
2: 2nd step
3: 3rd step
4: 4th step
5: 5th step
6: Maximal
Sensitivity
-
-
-
x
-
rw
UInt 16
0: Minimal
1: 2nd step
2: 3rd step
3: 4th step
4: Maximal
5: Auto
153
Light threshold
-
-
x
-
-
rw
UInt 16
0: Lowest
1: Low
2: Middle
3: High
155
Key lock active
-
-
x
-
-
rw
UInt 16
0: Display active if locked
1: Display inactive if locked
200
Save zero reset
x
x
x
x
-
w
UInt 16
Write any value to perform zero reset
201
Cancel zero reset
x
x
x
x
-
w
UInt 16
Write any value to delete zero reset
202
Teach-in 1 point
x
x
-
-
-
w
UInt 16
1: CH1
2: CH2
Teach-in far
-
-
x
-
-
w
UInt 16
Write any value to perform teach
203
Teach-in 2 point
x
x
-
-
-
w
UInt 16
See index 202
Teach-in near
-
-
x
-
-
w
UInt 16
See index 202
204
Teach-in ObSB
-
-
x
-
-
w
UInt 16
See index 202
210
Reset
x
x
x
-
-
w
UInt 16
3: Execute
211
Return to start menu
x
x
x
-
-
w
UInt 16
Write any value to return to start menu
212
Reset to factory set‐
tings
x
x
x
x
-
w
UInt 16
3: Execute
The module parameters of other, e.g., future modules, can also be stored in their documentation.
11.7.6
Smart Tasks
Smart Tasks process the various Smart Sensor signals for detection and measurement, linking them to binary
switching signals from an external sensor if necessary. These signals can be imported via pin 2 (see Pin 2 configu‐
ration, ISDU 121). The Smart Task uses this data to generate the requisite process information – tailored to the
task at hand in the plant. This saves time during data evaluation in the control, accelerates machine processes,
and makes high-performance, cost-intensive additional hardware unnecessary.
•
Decentralized signal analysis directly at the sensor
•
Faster signal capture and processing
•
Through Smart Tasks, Smart Sensors deliver the information that the plant process actually requires – no
separate data preparation necessary in the control
ANNEX
11
8025143/2020-01-23 | SICK
O P E R A T I N G I N S T R U C T I O N S | WI180C-IOA00
55
Subject to change without notice