11.7.4
Installation / Diagnostics
11.7.4.1
Device status
Table 32: Installation / Diagnostics – Device status
ISDU
Name
Data type
Data Stor‐
age
Length
Access
Default
value
Value/range
Index
Sub-
index
DEC
HEX
36
24
-
Device status
UInt
-
8 bits
ro
0 = Device is OK
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
5 ... 255 = Reserved
37
25
Detailed Device Status
Array
15 bytes
Octet string [5]
226
E2
0
System state
Record
2 bytes
1
Input signal state Pin 2
1 bit (offset: 7 bits)
true = External input HIGH
false = External input LOW
1)
Current status of switching output Qint 1
11.7.4.2
Device temperature
Table 33: Installation / Diagnostics – Temperature
ISDU
Name
Data type
Data Stor‐
age
Length
Access
Default
value
Value/range
Index
Sub-
index
DEC
HEX
153
99
0
Temperature
Record
-
1 Byte
ro
Internal device temperature in °C
1
Current temperature
8 bits (offset: 0 bits)
-127 ... 127
Read out the operating temperature of the sensor.
11.7.4.3
Operating hours
Table 34: Installation / diagnostics – Operating hours
ISDU
Name
Data type
Data Stor‐
age
Length
Access
Default
value
Value/range
Index
Sub-
index
DEC
HEX
190
BE
0
Operating hours
Record
-
4 bytes
ro
1
Total operating hours
Bit
32 bit
(offset: 0 bits)
80
0 ... 1,000.000
1)
1)
Running count of the operating hours of the sensor [h]
11.7.5
System-specific ISDUs
11.7.5.1
Profile property
Table 35: System-specific ISDUs – Profile property
ISDU
Name
Data type
Data reposi‐
tory
Length
Access
Default
value
Value/range
Index
Sub-
index
DEC
HEX
13
0D
-
Profile property
Array
-
8 bytes
ro
-
UInt 16 [4]
The
Profile property
specifies which standardized profiles and functions the sensor supports.
The values are transmitted in 5 blocks of 16 bits.
The following profiles/functions, at most, are supported:
1
PID (Profile Identifier) “Smart Sensor Profile”.
32768
Device identification
The device supports enhanced identification options, see “Identification” chapter.
32769
Binary data canal
The device provides switching signals in the specified manner.
ANNEX
11
8025143/2020-01-23 | SICK
O P E R A T I N G I N S T R U C T I O N S | WI180C-IOA00
49
Subject to change without notice