![SICK WI180C-IOA00 Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/sick/wi180c-ioa00/wi180c-ioa00_operating-instructions-manual_1264708036.webp)
Description
Value
Delay function
Deactivated
Switch-on delay
Switch-off delay
Switch-on/switch-off delay
Pulse (one shot)
Inverter
Yes
IO-Link interface
Table 10: IO-Link interface
Description
Value
Protocol version
IO-Link V1.1
Communication details
COM3 (230.4 kBaud)
Cycle time
2.0 ms
Housing material
Polycarbonate
Process data length
16 Bytes
Process data structure
(5 analog outputs out of 16
modules)
Bit 0 ... Bit 1 = QL1 ... QL2
Bit 2 ... Bit 33 = Module 1 Qint.1 ... module 16 Qint.2
Bit 34 ... Bit 47 = Reserved
Bit 48 ... Bit 63 = Analog output 5
Bit 64 ... Bit 79 = Analog output 4
Bit 80 ... Bit 95 = Analog output 3
Bit 96 ... Bit 111 = Analog output 2
Bit 112 ... Bit 127 = Analog output 1
Process data structure
(7 analog outputs out of 7
modules)
Bit 0 -...Bit 1 = QL1 ... QL2
Bit 2 ... Bit 15 = Module 1 Qint.1 ... module 7 Qint.2
Bit 16 ... Bit 31 = Analog output 7
Bit 32 ... Bit 47 = Analog output 6
Bit 48 ... Bit 63 = Analog output 5
Bit 64 ... Bit 79 = Analog output 4
Bit 80 ... Bit 95 = Analog output 3
Bit 96 ... Bit 111 = Analog output 2
Bit 112 ... Bit 127 = Analog output 1
Vendor ID
26
Device ID HEX
0x80022E
Device ID DEC
8389166
Internal system bus
Table 11: Internal system bus
Description
Value
Protocol version
V1
Max. number of modules
that can be connected
16
Ambient environment
Table 12: Ambient environment
Description
Value
Electromagnetic compati‐
bility (EMC)
EN 60947-5-2
Impact load
500 m/s² (50 G)
10
TECHNICAL DATA
36
O P E R A T I N G I N S T R U C T I O N S | WI180C-IOA00
8025143/2020-01-23 | SICK
Subject to change without notice