11.7
Service data
Service data is only exchanged between the control and IO-Link device via the IO-Link Master on request by the
control (acyclically). The service data is designated as ISDU's. ISDU's allow the user to read information about the
status of the connected IO-Link device and/or write new parameters to change the configuration.
The respective counterpart confirms receipt of the data.
If the IO-Link device does not answer within five seconds, the master reports a communication error.
11.7.1
Device identification
11.7.1.1
Direct parameters
Table 20: Device identification – Direct parameters 1 / 2
ISDU
Name
Data type
Data Stor‐
age
Length
Access
Default value
Value/range
Index
Sub-
index
DEC
HEX
0
00
-
Direct Parameters 1
Record
-
16 bytes
rw
1
01
-
Direct Parameters 2
-
Device identification
Table 21: Device identification
ISDU
Name
Data type
Data Stor‐
age
Length
Access
Default
value
Value/range
Index
Sub-
index
DEC
HEX
16
10
-
Vendor name
String
-
7 bytes
ro
SICK AG
18
12
Product name
12 bytes
WI180C-
IOA00
19
13
Product ID
7 bytes
6071650
219
DB
0
Article no. all components
Record
39 bytes
1
Article No. WI IO-Link Gate‐
way
7 bytes (offset:
256 bits)
6071650
2
Article no. of module 1
16 bits (offset:
240 bits)
4353
0 = ---
4353 = WLL180T (1 output)
4354 = WLL180T (2 outputs)
4369 = KTL180 (1 output)
4370 = KTL180 (2 outputs)
4865 = OD1 (15 mm model) on AOD1
4866 = OD1 (35 mm model) on AOD1
4867 = OD1 (100 mm model) on AOD1
4897 = OL1 on AOD1
5376 = Empty AOD1 channel
65535 = ERROR
3
Article no. of module 2
16 bits (offset:
224 bits)
4354
4
Article no. of module 3
16 bits (offset:
208 bits)
4369
5
Article no. of module 4
16 bits (offset:
192 bits)
4370
6
Article no. of module 5
16 bits (offset:
176 bits)
4865
7
Article no. of module 6
16 bits (offset:
160 bits)
4866
8
Article no. of module 7
16 bits (offset:
144 bits)
4867
9
Article no. of module 8
16 bits (offset:
128 bits)
4897
10
Article no. of module 9
16 bits (offset:
112 bits)
0
11
Article no. of module 10
16 bits (offset:
96 bits)
0
12
Article no. of module 11
16 bits (offset:
80 bits)
0
13
Article no. of module 12
16 bits (offset:
64 bits)
0
14
Article no. of module 13
16 bits (offset:
48 bits)
0
15
Article no. of module 14
16 bits (offset:
32 bits)
0
16
Article no. of module 15
16 bits (offset:
16 bits)
0
17
Article no. of module 16
16 bits (offset:
0 bits)
0