Configuration and operation
8.1
Detection area
With the Visionary-B you can configure up to two independent detection zones. Depending on the requirement they
can be connected or placed freely. In consideration of the zone limits the direction is free configurable.
8.1.1
Zone limits
IMPORTANT!
Full performance zone means that the performance within this zone was fully validated
not only in the lab, but also in the field, under real outdoor environment.
Full performance zone
Object class 1
Object class 2
Direction
Min. value
Max. value
Min. value
Max. value
Y (length)
0.3 m
6.0 m
1.5 m
5.0 m
X (width)
-2.0 m
2.0 m
-2.0 m
2.0 m
Full performance for object class 1
Full performance for object class 2
IMPORTANT!
The provided "Extended Zone" goes beyond the boundaries of the "Full Performance
Zone". The "Extended Zone" represents a transition region of reliable detection.
A degraded alarm behavior is possible within the "Extended Zone".
"Extended Zone" means performance withing this zone is fully validated in the lab, but
not fully validated in the field, under real outdoor environment.
Extended zone
Object class 1
Object class 2
Direction
Min. value
Max. value
Min. value
Max. value
Y (length)
0.3 m
7.0 m
1.2 m
6.0 m
X (width)
-3.0 m
3.0 m
-2.5 m
2.5 m