Technical specifications
Minimum
Typical
Maximum
Lighting
Wavelength
850 nm
Occular safety
Photobiologically harmless (IEC 62
471-7)
Housing
Material
Aluminium die cast
Dimensions
See section 11.2 “Dimensional drawings” on
page 56.
Total weight
0.355 kg
Reflective tape (length × width)
for resolution:
20 mm
1.00 m × 37 mm
24 mm
1.20 m × 37 mm
30 mm
1.50 m × 48 mm
Power-up delay after connecting
the supply voltage
6 s
Electrical data
Supply voltage V
S
at the device
(SELV)
19.2 V
24 V
28.8 V
Permissible cable resistance on
the supply cable
1 Ω
Residual ripple
°
5
%
Operating current
at 24 V without output load
165 mA
with maximum output load
690 mA
Power consumption
at 24 V without output load
4 W
with maximum output load
19 W
Electrical connection
M12
×
8 (see section 5.1 on page 32)
Cable length for wire cross-section
0.25 mm²
7.5 m
Synchronisation
Electrical (see section 5.1 on page 32)
4)
To meet the requirements of the relevant product standards (e.g. IEC 61
496-1), the external voltage supply
for the devices (SELV) must be able to bridge a brief mains failure of 20 ms. Power supplies according to
EN 60
204-1 satisfy this requirement. Suitable power supplies are available as accessories from SICK (see
section 12.2 “Accessories” on page 59).
5)
A fuse rated maximum 2 A shall be installed in the isolated 24 V DC power supply circuit to the device in order
to limit the available current.
6)
Within the limits of V
S
.