Operating Instructions
Chapter
13
V200/V300
8012227/YT87/2016-03-29
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
61
Subject to change without notice
Annex
13.2 Checklist for the manufacturer
Κ
Checklist for the manufacturer/installer for the installation of electro-sensitive protective equipment (ESPE)
Details about the points listed below must be present at least during initial commissioning — they are, however, dependent on the
respective application, the specifications of which are to be controlled by the manufacturer/installer.
This checklist should be retained and kept with the machine documentation to serve as reference during recurring tests.
1. Have the safety rules and regulations been observed in compliance with the directives/standards applicable to
the machine?
Yes
No
2. Are the applied directives and standards listed in the declaration of conformity?
Yes
No
3. Does the protective device comply with the required PL/SILCL and PFHd as per EN ISO 13
849-1/EN 62
061 and
the type as per IEC 61
496-1?
Yes
No
4. Is the access to the hazardous point only possible through the protective field of the ESPE?
Yes
No
5. Have appropriate measures been taken to protect (mechanical protection) or monitor (protective devices) any
persons or objects in the hazardous area when protecting a hazardous area or hazardous point, and have these
devices been secured or locked to prevent their removal?
Yes
No
6. Are additional mechanical protective measures fitted and secured against manipulation which prevent reaching
under, over or around the ESPE?
Yes
No
7. Has the maximum stopping and/or stopping/run-down time of the machine been measured, specified and
documented (at the machine and/or in the machine documentation)?
Yes
No
8. Has the ESPE been mounted such that the required minimum distance from the nearest hazardous point has
been achieved?
Yes
No
9. Are the ESPE devices correctly mounted and secured against manipulation after adjustment?
Yes
No
10. Are the required protective measures against electric shock in effect (protection class)?
Yes
No
11. Is the control switch for resetting the protective device (ESPE) or restarting the machine present and correctly
installed?
Yes
No
12. Are the outputs of the ESPE (OSSD) integrated according to required PL/SILCL compliant with
EN ISO 13849-1/EN 62061 and does the integration correspond to the comply with the circuit diagrams?
Yes
No
13. Has the protective function been checked in compliance with the test notes of this documentation?
Yes
No
14. Are the specified protective functions effective at every operating mode that can be set?
Yes
No
15. Are the switching elements activated by the ESPE, e.g. contactors, valves, monitored?
Yes
No
16. Is the ESPE effective over the entire period of the dangerous state?
Yes
No
17. Once initiated, will a dangerous state be stopped when switching the ESPE on or off and when changing the
operating mode, or when switching to another protective device?
Yes
No
18. Has the information label for the daily check been attached so that it is easily visible for the operator?
Yes
No
This checklist does not replace the initial commissioning, nor the regular inspection by qualified safety personnel.