Mounting
4.4.2
Mounting in a frame
⋅
Always mount the camera with at least two screws and use the fastening openings on
two opposite sides of the housing.
⋅
Secure the two fixing screws against unintentional loosening.
⋅
Always use washers under the screws (cf. figure).
⋅
Use sliding nuts suitable for the profile system employed for mounting the camera.
⋅
Pay attention to the thickness of the flange on the camera when selecting a suitable
screw length (see section 11.2 “Dimensional drawings” on page 56).
Protect unmonitored areas using mechanical guards!
⋅
Take organisational measures to protect the un-monitored areas (see section 4.3
“Avoiding unmonitored areas” on page 24).
Fig. 15: Mounting in a frame
Notes
WARNING