Chapter
11
Operating Instructions
V200/V300
52
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8012227/YT87/2016-03-29
Subject to change without notice
Technical specifications
11
Technical specifications
11.1 Data sheet
Minimum
Typical
Maximum
General system data
Protective field dimensions
See section 4.1 “Checking the dimensions of the
protective field” on page 18ff.
Type
V200 Work Station Extended
2 (IEC 61
496-1, IEC/TR 61
496-4)
V300 Work Station Extended
3 (IEC 61
496-1, IEC/TR 61
496-4)
Safety integrity level
V200 Work Station Extended
SIL1 (IEC 61
508)
V300 Work Station Extended
SIL2 (IEC 61
508)
SIL claim limit
2)
V200 Work Station Extended
SILCL1 (EN 62
061)
V300 Work Station Extended
SILCL2 (EN 62
061)
Category
V200 Work Station Extended
2 (EN ISO 13
849-1)
V300 Work Station Extended
3 (EN ISO 13
849-1)
Performance Level
2)
V200 Work Station Extended
PL c (EN ISO 13
849-1)
V300 Work Station Extended
PL d (EN ISO 13
849-1)
Test rate
50 ¹/
s
(EN ISO 13
849-1)
Demand rate
30 ¹/
min
(EN ISO 13
849-1)
PFHd (mean probability of a
dangerous failure per hour)
5.6 × 10
–9
T
M
(mission time)
20 years (EN ISO 13
849)
Protection class
III (EN 50
178)
Enclosure rating
IP 54 (EN 60
529)
Resolution
20 mm, 24 mm or 30 mm
Field of view
103° ± 3°
Ambient operating temperature
–5 °C
+50 °C
Storage temperature
–25 °C
+70 °C
(
′
24 h)
Humidity, taking into account the
operating temperature range
IEC 61
496-1, section 5.1.2 and section 5.4.2 as
well as IEC/TR 61
496-4, section 5.4.2
Air humidity (non-dewing)
15
%
95
%
Sinusoidal vibration
5 g, 10–55 Hz (EN 60
068-2-6)
Shock resistance
10 g, 16 ms (EN 60
068-2-27)
2)
For detailed information on the safety design of your machine/system, please contact your local SICK
representative.
3)
For V200 Work Station Extended the following applies: Between two demands for a safety-related reaction
from the device, at least 100 internal or external tests must be performed.
Tab. 15: Data sheet
V200/V300