![SICK V200 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/sick/v200/v200_operating-instructions-manual_1264329017.webp)
Operating Instructions
Chapter
3
V200/V300
8012227/YT87/2016-03-29
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
17
Subject to change without notice
Product description
3.5.2
Diagnostics LEDs of the V200/V300
The camera indicates diagnostic information with the aid of four LEDs.
Display
Meaning
Ν
1
…
Ν
2
…
Ν
3
…
Ν
4
Power-up sequence: After switching on the V200/V300 and after each
teach-in, the power up sequence runs. Starting with the diagnostics
LED 1, the next diagnostics LED illuminates after one second and so
on until all 4 diagnostics LEDs are illuminated.
ν
Protective field sector free
Ν
Interruption of the protective field in the allocated protective field
sector (see Fig. 8). A protective field sector represents one quarter of
the field of view of the V200/V300.
⌠Ε
Teach-in mode (see section 8.1 “Teach-in” on page 44)
⌠Ι
Warning (see chapter 10 “Fault diagnosis” on page 50)
⌠ϑ
Error (see chapter 10 “Fault diagnosis” on page 50)
Fig. 8: Diagnostics LEDs
of the V200/V300
Tab. 5: Meaning of the
diagnostics LEDs
Diagnostics LEDs
Allocation of the
diagnostics LEDs
to the protective
field sector