3
2
1
Figure 10: Triple field mode
1
2
3
When using simultaneous monitoring, the safety laser scanner can monitor two field
sets at the same time (e.g., hazardous area on the left, and hazardous area on the
right). When used in conjunction with a Flexi Soft safety controller that provides multiple
OSSD pairs, this can be used, for example, to independently protect two machines
using only one safety laser scanner.
If two field sets are simultaneously configured with dual protective fields, four protective
fields can be monitored at the same time. This, in conjunction with a Flexi Soft safety
controller, allows up to four independent hazardous areas to be monitored for safety at
the same time.
3
PRODUCT DESCRIPTION
22
O P E R A T I N G I N S T R U C T I O N S | S3000 Cold Store
8012029/ZA20/2019-11-14 | SICK
Subject to change without notice