Supplement to prevent reaching over
•
Height of the scan plane
•
Switching time between monitoring cases, if applicable
Calculate the minimum distance S using the following formula (see ISO 13855):
b
S = (K × (T
M
+ T
S
)) + Z
G
+ Z
R
+ C
where
•
K = Approach speed (1,600 mm/s, defined in ISO 13855)
•
T
M
= Stopping time of the machine or system
•
T
S
= Response time of the safety laser scanner and the downstream controller
•
Z
G
= General supplement = 100 mm
•
Z
R
= Supplement for reflection-related measurement errors
•
C = Supplement to prevent reaching over
S
of the safety laser scanner
S
of the safety laser scanner depends on the:
•
Basic response time of the safety laser scanner
•
Set multiple sampling
•
Transmission speed to external OSSDs via EFI
Supplement Z
R
for reflection-related measurement errors
DANGER
Persons or parts of the body to be protected may not be recognized or not recognized in
time in case of non-observance.
Retro-reflectors at a distance of less than 1 m from the protective field boundary can
dazzle the safety laser scanner and impair its detection capability.
b
Avoid retro-reflectors at a distance of less than 1 m to the protective field bound‐
ary.
b
If retro-reflectors are nevertheless mounted at a distance of less than 1 m from
the protective field boundary, add a supplement Z
R
= 200 mm to the protective
Supplement C to protect against reaching over
With a protective field installed horizontally, there is a risk of people reaching over the
protective field and thereby reaching the hazardous area before the safety laser scan‐
ner shuts down the dangerous state. You need to allow for this by incorporating a sup‐
plement into the calculation of the minimum distance. This will prevent people from
reaching over the protective field and getting into a hazardous situation (see
ISO 13857) before the safety laser scanner responds.
1
2
H
D
= 0
C = 1200
C = 850
H
D
= 875
Figure 32: Risk of reaching over (mm)
4
PROJECT PLANNING
40
O P E R A T I N G I N S T R U C T I O N S | S3000 Cold Store
8012029/ZA20/2019-11-14 | SICK
Subject to change without notice