Commissioning and
configuration
Step 3
Interrupt within the next 30 s the safety light curtain’s protective
field at the ends until the COM LED flashes
White
1× (after
approx. 3 s).
Remove the interruption within the next 30 s.
The direction indicated by the LEDs 1 to 5
Blue
points toward
the inside; they indicate the next interruption is in the middle.
Keep the safety light curtain’s protective field clear until the COM
LED flashes
White
1× (after approx. 3 s).
Step 4
Again interrupt within the next 30 s the safety light curtain’s
protective field in the middle until the COM LED flashes
White
1× (after approx. 3 s).
Remove the interruption within the next 30 s.
The direction indicated by the LEDs 1 to 5
Blue
points toward
the ends; they indicate the next interruption is at the ends.
Keep the safety light curtain’s protective field clear until the COM
LED flashes
White
1× (after approx. 3 s).
Step 5
Interrupt within the next 30 s the safety light curtain’s protective
field at the ends until the COM LED flashes
White
1× (after
approx. 3 s).
Remove the interruption within the next 30 s.
Keep the safety light curtain’s protective field clear until the COM
LED flashes
White
and the LEDs 1 to 5 flash
Blue
3×
(after approx. 3 s).
Step 6
Switch off the safety light curtain within the next 2 minutes.
The next time switched on, EDM and Reset are deactivated.
Step 7
Then configure the required functions (see sections 6.5 and 6.6
on page 55)
Check the effectiveness of the protective device as described in
section 6.7 “Test notes” on page 56.
If the COM LED flashes
White
2× in succession during deactivation, the procedure has
been interrupted. In this case, repeat the complete procedure.
Note