Mounting
How to mount the miniTwin2 with C
C
Fix brackets:
The C
A
Fix bracket can not be used on a device with a protective field height of 120 mm.
Mount the C
A
Fix brackets ( ) such that the Twin Stick is positioned at the correct
height.
In applications in which juddering and vibration can occur as well as for sizes
V
360 mm
we recommend mounting the brackets a distance of one quarter of the length of the
Twin Stick from the end of the Twin Stick.
Fasten the M5 screws to a torque approx. 3 Nm. Higher torques can damage the
brackets; lower torques provide inadequate protection against displacement.
Fit the Twin Stick in the C
A
Fix brackets and press it down gently ( ).
Rotate the Twin Stick to the rear until it engages in the C
A
Fix brackets ( ).
Move the Twin Stick to the required position.
Fasten the M3 screws for the C
A
Fix brackets to a torque of approx. 1.5 Nm to fix the
Twin Stick ( ).
Note
Recommendation
Fig. 22: Mounting of the
miniTwin2 with C
@
Fix brackets
¼L
¼L
½L