Product description
3.5.2
External device monitoring (EDM)
The EDM checks if the contactors actually de-energize when the protective device
responds. If you activate external device monitoring, then the miniTwin2 checks the
contactors after each interruption to the light path and prior to the machine restart. The
EDM can so identify if one of the contactors has welded, for instance. In this case the
external device monitoring places the system in a safe operational state. The OSSDs are
not re-activated in this case.
The electrical connection for the external device monitoring is described in section 5.5
“External device monitoring (EDM)” on page 49.
Section 6.6 “Configuration of the external device monitoring (EDM)” on page 56
describes how to configure the function.