Chapter
3
Operating Instructions
miniTwin2
18
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
8013482/YT85/2016-02-23
Subject to change without notice
Product description
3.5
Configurable functions
This section describes the functions of the miniTwin2 safety light curtain that can be
configured.
Test the protective device after any changes!
Changes to the configuration of the devices can degrade the protective function. After
every change to the configuration you must therefore check the effectiveness of the
protective device (see section 6.7 “Test notes” on page 56).
The person who makes the change is also responsible for the correct protective function of
the device.
Reset and external device monitoring can be configured on the miniTwin2 safety light
curtain.
Reset is configured by activating the reset button with a specific cycle (see section 6.5
“Configuration of the Reset function” on page 55).
If the input is wired correctly to the contactors, the external device monitoring (EDM) is
configured automatically the first time the OSSDs are switched (see sections 5.5
“External device monitoring (EDM)” on page 49 and 6.6 “Configuration of the external
device monitoring (EDM)” on page 56).
WARNING
Fig. 8: Configurable functions
K1
K2
k1
k2
Reset button
OSSD1
OSSD2
EDM
24 V DC
0 V DC