Commissioning and
configuration
6.3
Default delivery status
As delivered the miniTwin2 safety light curtain is configured as follows:
reset: deactivated
external device monitoring (EDM): deactivated
6.4
Configuration of protective operation without Reset
and/or without EDM
If you configure the miniTwin2 safety light curtain in protective operation without Reset
and/or without EDM, you must connect the related multifunction connection or both
multifunction connections to 0 V. Otherwise the system locks completely 4 minutes after
switching on (lock
A
out).
6.5
Configuration of the Reset function
To activate the Reset function, a reset button must be connected to the miniTwin2 safety
light curtain (see section 5.4 on page 48).
You have 4 minutes to configure the function after switching on the safety light curtain.
Otherwise the system locks completely 4 minutes after switching on (lock
A
out).
How to activate the Reset function of the miniTwin2:
Ensure the system or machine is in a safe condition!
While you configure the safety light curtain, the system or the machine could start
unintentionally. Ensure that the whole system or machine is in a safe condition during the
configuration process.
Ensure that the whole system or machine is in a safe condition.
Switch the safety light curtain on.
The RES LED flashes
Orange
and the EDM LED flashes
Orange
.
Press the reset button within 4 minutes of switching on.
After approx. 1 second the EDM LED
Orange
goes out.
Release the reset button within the next 2 seconds.
After you release the reset button, the RES LED
Orange
flashes, reset is mandatory.
The configuration has been successfully completed.
If the protective field is obstructed, the RES LED illuminates
Orange
.
Ensure that the system or the machine is in a safe condition.
Then check the Reset function. If Reset has not been activated, then repeat the whole
process.
If during the configuration the reset button is released too late, the function is not
activated. The RES LED flashes
Orange
and the EDM LED flashes
Orange
.
Release the reset button within three seconds and repeat the configuration. If the
button is not released within this period, the system locks completely (lock
A
out).
Reset is stored in non-volatile memory in the device. The function can only be deactivated
by consciously resetting the configuration (see section 6.8 “Deactivating Reset and EDM”
on page 58).
WARNING
Note