Technical specifications
Minimum
Typical
Maximum
Output signal switching devices
(OSSD)
PNP semiconductors, short-circuit protected
,
cross-circuit monitored
Response time standalone
device with 14 mm resolution
(Protective field height
120 … 720 mm)
14 ms
Response time standalone
device with 14 mm resolution
(Protective field height
780 … 1200 mm)
17 ms
Response time standalone
device with 24 or 34 mm
resolution
13 ms
Additional response time for
cascaded systems (host/guest)
2 ms
Additional response time for
cascaded systems
(host/guest/guest)
4 ms
Switch off time
80
ms
Power-up delay
200 ms
Switching voltage
HIGH
(active, U
rms
)
V
S
– 2.2 V
24 V
V
S
Switching voltage LOW
(inactive)
0 V
0 V
2 V
Switching current
0 mA
300 mA
Leakage current standalone
13)
0.25 mA
Leakage current cascaded
system
13)
0.5 mA
Load capacity
1
µ
F
Switching sequence
Depending on load inductance
Load inductance
2.2 H
Test pulse data
15)
Test pulse width
120
µ
s
150
µ
s
300
µ
s
Test pulse rate
3
1
/s 5
1
/s 10
1
/s
Permissible cable resistance
1.29
\
Power consumption
3 A (host/
guest/guest)
16)
9)
Applies to the voltage range between –30 V and +30 V.
10)
As per IEC 61 496
A
2.
11)
As per IEC 61 131
A
2.
12)
On the device plug.
13)
In the case of a fault (0 V cable open circuit) the maximum leakage current flowing in the OSSD cable. The
downstream controller must detect this status as LOW. A FPLC (fail-safe programmable logic controller) must
be able to identify this status.
14)
The maximum rated load inductance is higher with lower switching sequence.
15)
When active, the outputs are tested cyclically (brief LOW). When selecting the downstream controllers, make
sure that the test pulses do not result in deactivation when using the above parameters.
16)
Maximum power consumption of a system with 1200 mm protective field height and a resolution of 14 mm.