Operating instructions
Chapter
10
ICR 84x Image Code Reader
Appendix
8 010 961/0000/10-05-2005
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-9
10.3.5
Functions
The CLV Setup program (from V 4.1) features functions to carry out the following:
•
Loading the default setting of the parameter set from the database of CLV Setup
•
Automatic communication attempt with the ICR when the program is started
•
Automatic software compatibility check in the ICR
•
Uploading and displaying parameter set stored in the ICR
•
Changing the parameter/parameter values on the tabs
•
CLV Assistant for simplified parameterization
•
Downloading the changes to the parameter set in the ICR
•
Saving the changes to the parameter set as a configuration file “*.scl“
•
Printing the configuration files
•
Exporting the configuration files in RTF format
•
Exporting the command strings contained in the profile bar codes in ASCII format
•
Printing the parameter set in the form of profile bar codes
•
Organizing serveal scanners logically by projects
•
Online access to the ICR via a Terminal Emulator (selecting operating mode, starting
operating functions, logging file for communication between the ICR and CLV Setup,
extended terminal mode, e.g. for displaying ICR messages)
•
AutoBaud detect for automatic communication establishment with the ICR
•
Selecting the COM port of the PC for adapting the data transfer parameters
•
Monitor the data communication of the ICR host interface
•
Selecting the display language
•
Selecting the units of measure
•
Displaying the last 10 configuration files that were processed
•
Saving the device type that was selected last
•
Automatic storage confirmation prompt when changes are made to the configuration
file
•
Wizards for individual functions
•
Clearing the optional CMC 400 parameter memory in the CDB/CDM Connection
Module
•
Image output of the read code via the Ethernet interface (ICR only)
•
Setting switches in the “CLVmain.ini“ file for starting the program
•
Hot keys [F keys] for essential functions (program operation without a mouse)
•
Starting program with SCL file as argument
•
Macro player for recording and playing a macro file
•
Context-sensitive help via the
[
F1
]
key
10.3.6
Hot keys
[F1]
Start "CLV Setup Help“ online
[F2]
Open dialog box to execute device functions
[F3]
Upload complete set of parameters from CLV
[F4]
Download complete set of parameters to CLV
[F5]
Open configuration file
[F6]
Save configuration file