![SICK ICR 84x Скачать руководство пользователя страница 99](http://html.mh-extra.com/html/sick/icr-84x/icr-84x_operating-instructions-manual_1264250099.webp)
Operating instructions
Chapter
6
ICR 84x Image Code Reader
Operation
8 010 961/0000/10-05-2005
©
SICK AG · Division Auto Ident · Germany · All rights reserved
6-45
6.6
ICR messages
The ICR outputs encoded system and error messages via the terminal interface to report
user actions or events in the reading process. When the system is started, the ICR also
outputs system messages in plain text (English). If configured accordingly, the ICR transfers
the error status ST in the data output string of the host interface.
6.6.1
Displaying messages
In the 4th field from the left in the status bar at the bottom of the screen, CLV Setup displays
system and error messages that occur at the terminal interface of the ICR. These are
recorded in a file, which is continuously updated. The messages have the following format:
•
System message: "ICR SYS-Message: xxx"
•
Error message:
"ICR SYS-Error: 048ID8xxx"
The additional system messages in plain text can be displayed in the terminal emulator if
CLV Setup and the terminal emulator are started before the ICR is connected.
Additional system messages:
When the system is started, these system messages inform the user whether the starting
process was successful. No further measures are normally required.
example.
Chapter 10.2 “System messages“, Page 10-2
explains the meaning of the messages.
Fig. 6-33: CLV Setup: Displaying the system messages in the Terminal Emulator when starting the
ICR