Chapter
6
Operating instructions
ICR 84x Image Code Reader
6-18
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 010 961/0000/10-05-2005
Operation
Loading complete parameter set from the ICR (Upload)
¾
Click
in the toolbar or press [F3] key.
CLV Setup loads the current ICR parameter set from the RAM of the ICR to its database
and displays the values on the tabs.
The “Device Ready“ LED is extinguished during the upload.
If the “CLV Setup“ program does not recognize the parameters transferred during the
upload, it outputs a warning. Unknown parameters can be edited on the E
XTRAS
tab by
following the conventions for command strings. When the parameter set is saved, these
parameters are also taken into account.
Transferring the complete parameter set to the ICR and saving it (Download)
1.
Click
in the toolbar or press [F4] key.
The “Device Ready“ LED is extinguished.
CLV Setup copies the parameter set to the RAM of the ICR.
The D
OWNLOAD
P
ARAMETERS
dialog box with the save options is then displayed.
P
ERMANENT
:
CLV Setup copies the parameter set to the RAM
and
to the EEPROM of
the ICR.
T
EMPORARY
:
CLV Setup copies the parameter set to the RAM only. The changes are
lost when the ICR power supply is switched off.
2.
Confirm the dialog box with the desired save option.
The “Device Ready“ LED lights up again.
The new parameter set is stored in the ICR either permanently or temporarily dependent of
the selected option.
Saving the parameter set in CLV Setup
1.
To save the modified parameter set as a new configuration file in CLV Setup or to
overwrite an existing file, select the menu F
ILE
and the menu item S
AVE
A
S
.
The S
AVE
AS
dialog box is then displayed.
2.
Enter the file name in the dialog box (file extension “*.scl“) and confirm the
entry.
The new parameter set is now saved in CLV Setup in the subdirectory “data“.