13. Click N
EXT
.
The Assistant transfers the determined values to CLV Setup and closes.
The Ethernet connection is interrupted (“
No Connection
“ displayed in red).
The ICR is ready for operation with the settings generated by AutoSetup.
14. You can check the values in CLV Setup on the R
EADING
CONFIGURATION
and D
ATA
M
ATRIX
tabs. The data only needs to be downloaded to the ICR if any other parameters (reading
trigger, data output) are changed manually.
15. To restart the communication with the ICR, double-click on the displayed IP address/
port in the status line at the bottom left (grey frame).
16. The I
NTERFACE
O
PTIONS
dialog box is then displayed:
17. Click OK.
CLV Setup restarts the communication with the ICR.
18. If the ICR again reads the DataMatrix code successfully, ImageFTP displays the reading
diagnosis data when enabled for outputting (
).
Fig. 6-20: CLV Setup: Status line with IP address/port of the Ethernet connection
Fig. 6-21: CLV Setup: “Interface Options“ d