background image

Keyscan Inc. A Member of the Kaba Group 

901 Burns St. E., Whitby, Ontario, Canada L1N 0E6 
1.888.539.7226 (toll free Canada/USA) 
905.430.7226 (elsewhere) 

 

www.keyscan.ca  
Technical Support 
Hours 

 9:00 AM to 6:30 PM Eastern Time 

K-SMART3 Installation Guide (Document # KD10085-1017) 

 

 FCC Compliance Statement: This device complies with part 15 of the FCC rules. Operation 

is subject to the following two conditions: (1) this device may not cause harmful interfer-
ence, and (2) this device must accept any interference received, including interference 
that may cause undesired operation. 

 

 
Product can be used without license conditions or restrictions in all European Union coun-
tries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, 
Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxem-
bourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain, Sweden, United 
Kingdom, as well as other non-EU countries, including Iceland, Norway, and Switzerland. 
 
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is 
subject to the following two conditions: (1) this device may not cause interference, and 
(2) this device must accept any interference, including interference that may cause unde-

sired operation of the device. 
 
Cet appareil est conforme à Industrie Canada exempts de licence standard RSS (s) . Le 
fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas 

provoquer d’interférences et (2) ce dispositif doit accepter toute interférence, y compris 

les interférences qui peuvent causer un mauvais fonctionnement du dispositif. 
 

Note: This equipment has been tested and found to comply with the limits for a Class A 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio frequen-
cy energy and, if not installed and used in accordance with the instruction manual, may 
cause harmful interference to radio communications. Operation of this equipment in a 
residential area is likely to cause harmful interference in which case the user will be re-
quired to correct the interference at his own expense. 
 

Changes or modifications not expressly approved by Keyscan could void the user’s au-

thority to operate the equipment. 
 

 

  

K-SMART3 Bluetooth Proximity Reader 

Installation Guide 

This guide outlines how to install the K-SMART3 Bluetooth proximity reader. This reader 
has dedicated function LEDs and enhanced security features designed for Keyscan access 
control systems with compatible firmware. Enhanced security and LED features may not 
function with non-Keyscan control boards. See K-SMART3-ACU Compatibility on page 3. 

Keyscan Inc. A Member of the Kaba Group  

901 Burns Street East, Whitby, Ontario, Canada L1N 0E6 

K-SMART3 Features 

• 

Uses proven digital radio frequency 
identification technology 

• 

Has dedicated access and power LEDs 

• 

Designed for indoor or outdoor use 

• 

Suitable for mullion or single-gang 
mounting 

• 

Electronics sealed in tamper-resistant 
epoxy potting 

• 

Bluetooth functionality

 

Table of Contents 

Features 

LEDs & Security Features 

2-3 

Bluetooth Functionality 

Dimensions & Templates 

4-5 

Wiring Connections 

6  

Optional Programming Card 

Specifications 

Parts List 

K-SMART3 Reader  

Wall Switch Plate 

Mullion Mount Box 

6-

32 x 1/4” Phillips Screw

 

6-

32 x 1/4” Security Screw

 

6-

32 x 1” Screws

 

#6 x 1” Screws

 

Enhanced Features 

• 

Has dedicated Present3 and Global 
Lockdown LEDs 

• 

Offers physical and cable anti-tamper 
capability for enhanced security 
(tamper switch not included) 

• 

Has innovative heartbeat to detect 
wiring faults and/or reader damage 

 

Содержание K-SMART3

Страница 1: ...gned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequen cy energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful ...

Страница 2: ... and require System PROM firmware version 9 39 or higher 7 K SMART3 Enhanced Features K SMART3 enhanced features which include Heartbeat and Tamper are turned on by default With the purchase of the K PC2 programming card K SMART3 enhanced features can be toggled on and off This will enable backwards compatibility with previous versions of Keyscan ACUs even if they do not have the required firmware...

Страница 3: ... Compatibility The K SMART3 s enhanced features Present3 LED lockdown LED heartbeat and orange tamper conductor require PC1097 control boards with firmware version 9 39 or higher The K SMART3 is backwards compatible with PC1094 PC1095 and previous green ACU ECU control boards The K SMART3 can be used with other access control systems but the enhanced features will not be available To configure the...

Страница 4: ...4 Dimensions Mounting Template Wall Plate 3 4 1 9 cm KI 00580E 06 16 4 3 4 12 cm 3 7 6 cm TOP 5 Dimensions Mounting Template Mullion 1 11 16 4 49 cm TOP 3 4 1 91 cm 4 7 16 11 5 cm KI 00581E 06 16 ...