Kaba K-SMART3 Скачать руководство пользователя страница 2

K-SMART3 Overview 

LEDs and Security 
Features 

The K-SMART3 has 4 distinct 
LEDs to report the state of a 
system-specific function. In 
addition, the K-SMART3 has 
an anti-tamper capability 
and a heartbeat for en-
hanced reader security. The 
following sub-headings re-
view the K-

SMART3’s LED, 

anti-tamper and heartbeat 
functions. Control boards 
require System PROM ver-
sion 9.39 or higher when 
connected to a K-SMART3 
reader for full functionality; 
for example, using LED 3 for 
Present3 or LED 4 for Global 
Lockdown. 

KEYSCAN

KI-00556E-06-16

Secure reader to plate with 
enclosed security screw*.

 

2

3

4

* Both Phillips & 
#10 PIN Torx 
screws provided. 
Torx driver not 
included.

LED 1

Door Lock State 

• 

Red

indicates the door is locked / remains red on an Access Denied 

• 

Green

indicates the door is unlocked / green during Relay Unlock Time On and 

Access Granted 

 The control board must be configured for Reader LED (Red/Green Enabled) mode. 

 

LED 2

Power 

The backlit Keyscan logo indicates reader power: 

• 

Not illuminated

indicates the reader does not have power 

• 

Illuminated blue

indicates the reader has power 

LED 3

Present3 

The Present3 mode can trigger a door lock and change time zone schedules. When con-
figured for operation at the reader, LED 3 functions as follows: 

• 

Not illuminated

Present3 is off/Door Toggle - locked/Schedule - time zone is on 

• 

Illuminated amber

Present3 is on/Door Toggle - unlocked/Schedule - time zone is 

off 

LED 4

Global Lockdown 

LED 4 indicates when a Global Lockdown is in effect as follows: 

• 

Not illuminated

a Global Lockdown is not in effect 

• 

Illuminated red

a Global Lockdown is in effect 

The reader must be connected to a control board that has Global Lockdown configured. 

 

Note: 

LED 3

Present3 and LED 4

Global Lockdown are unique features for Keyscan 

control boards and require System PROM firmware version 9.39 or higher.   

K-SMART3 Enhanced Features 

K-SMART3 enhanced features, which include Heartbeat and Tamper, are turned on by 
default. With the purchase of the K-PC2 programming card, K-SMART3 enhanced features 
can be toggled on and off. This will enable backwards compatibility with previous versions 
of Keyscan ACUs, even if they do not have the required firmware 9.39 or higher to work 

with other manufacturer’s access control systems.

 

If the K-SMART3 enhanced features are used on an un-supported access control board, 
the reader will produce a Card Not in ACU alarm approximately every 60 seconds. This 

will not affect the reader’s ability to read cards.

 

 
Keep this programming card close at hand for future use with any K-SMART3 reader to 
toggle the enhanced features on or off. K-PC2 programming cards are available in pack-
ages of 5 individual cards.

 

Specifications 

Dimensions:  

Mullion: 11.5 cm x 4.49 cm x 1.7 cm (4 7/16” x 1 11/16” x 11/16”)

 

Wall Plate: 12 cm x 7.6 cm x 1.6 cm (4 3/4” x 3” x 5/8”) 

 

Power Requirements 

12 VDC, 125mA 

Read Range (with typical clamshell card) 

Off Metal: up to 3 cm   
On Metal: up to 3 cm 

Cable 

18” wire pigtail standard

 

Wiegand interface

22 AWG 6 conductor shielded cable, 152 metres/500 ft. maximum 

Environmental 

Operating Temperature: -40

 

to 66

 

°C  (-40

 

to 150.8

 

°F), 93% RH 

Installation  

Installation and wiring of systems must be in accordance with the National Electrical 
Code, ANSI/NFPA 70. 

 

Connections 

Connections must be in accordance with NFPA 70. Reader and/or control unit power 
sources must not be connected to a receptacle controlled by a switch. 

 

Certifications 

UL-294 - Fifth Edition, CAN/ULC-S319-5 - First Edition, FCC ID: WFW-KSMART3 & IC: 
5241A-KSMART3, ETSI EN 301 489-1 V2.1.1 (2017-02), ETSI EN 301 489-3 V2.1.1 
(2017-03), ETSI EN 301 489-17 V3.1.1 (2017-02), EN 55032: 2012/AC:2013, ETSI EN 
300 330 V2.1.1 (2017-02), ETSI EN 300 328 V2.1.1 (2016-11), Canadian Industrial De-
sign Certificate of Registration: 169,198 and 169,199. 

Содержание K-SMART3

Страница 1: ...gned to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequen cy energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful ...

Страница 2: ... and require System PROM firmware version 9 39 or higher 7 K SMART3 Enhanced Features K SMART3 enhanced features which include Heartbeat and Tamper are turned on by default With the purchase of the K PC2 programming card K SMART3 enhanced features can be toggled on and off This will enable backwards compatibility with previous versions of Keyscan ACUs even if they do not have the required firmware...

Страница 3: ... Compatibility The K SMART3 s enhanced features Present3 LED lockdown LED heartbeat and orange tamper conductor require PC1097 control boards with firmware version 9 39 or higher The K SMART3 is backwards compatible with PC1094 PC1095 and previous green ACU ECU control boards The K SMART3 can be used with other access control systems but the enhanced features will not be available To configure the...

Страница 4: ...4 Dimensions Mounting Template Wall Plate 3 4 1 9 cm KI 00580E 06 16 4 3 4 12 cm 3 7 6 cm TOP 5 Dimensions Mounting Template Mullion 1 11 16 4 49 cm TOP 3 4 1 91 cm 4 7 16 11 5 cm KI 00581E 06 16 ...

Отзывы: