OFF
uncoded
code 1
code 2
rev.conf.
ON
1
O
N
2
Figure 54: SP1 system plug with 2 DIP
switches
OFF
uncoded
code 1
code 2
rev.conf.
ON
1 2 3 4
O F F
1 2 3 4
O F F
1 2 3 4
O F F
1
O
N
2
A
B
C
D
Figure 55: SP2 system plug with 14 DIP
switches
Table 29: Overview of DIP switches
Row
DIP switch
Function
A
1)
1, 2, 3, 4
Muting,
see "Configuring muting", page 97
B
1)
1, 2
Scanning range adjustment,
3, 4
Reduced resolution,
C
1)
1
Smart presence detection,
smart presence detection", page 100
2
Not assigned
3
Smart Box Detection
2)
4
Parity,
see "Checking the parity", page 102
D
1, 2
•
Beam coding,
•
Reset to factory settings,
1)
Only applies to SP2 system plug.
2)
On devices with range of functions 1.0.0, DIP switch 3 is not assigned.
Configuration information
b
Check the parity using the SP2 system plug after setting the DIP switches. The
sum of the DIP switches of rows A, B and C set to On must be even. In case of an
uneven sum, change the setting of DIP switch 4 (row C).
b
Securely close the protective cover for the DIP switches, which is attached to the
SP2 system plug.
b
Then ensure the correct functioning of the device.
7
CONFIGURATION
92