NOTE
This document does not provide instructions for operating the machine in which the
safety light curtain is integrated.
Further topics
•
"Minimum distance to reflective surfaces", page 31
9.3
Regular thorough check
The thorough check is intended to ensure that the safety functions are fulfilling their
planned purpose and whether persons are being adequately protected.
b
Carry out the checks specified in the test plan of the manufacturer of the machine
and the operating entity.
9.4
LEDs
Sender
Position of LEDs:
see "Sender displays", page 21
.
If the sender and receiver are connected to each other by a cable, the LEDs on the
sender indicate the same status as the LEDs on the receiver during normal operation.
The STATE LED on the sender adopts the status of the OSSD LED on the receiver.
If the sender and receiver are not connected with each other, the STATE LED on the
sender lights up yellow when the sender is in operation and no faults are present.
Receiver
Position of LEDs:
see "Receiver displays", page 22
.
Table 41: LEDs on the receiver during normal operation
LEDs
End cap with inte‐
grated LED
Meaning
OSSD Field
Diagnostics LEDs
1
2
3
4
5
6
7
8
O
White
EDM is configured.
O
White
Cascade with 1 or
with 2 guest devices
is configured.
O
White
Beam coding 1 or 2
is configured.
O
White
Restart interlock is
configured.
O
White
Muting or partial
blanking is config‐
ured.
OR
Smart Box Detection
is configured.
O
White
Reduced resolution
is configured.
O
White
Scanning range
adjustment is config‐
ured.
OPERATION
9
8021645/1EB0/2022-04-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTec4
117