Further topics
•
•
"Configuring the restart interlock", page 103
•
"Configuring external device monitoring (EDM)", page 104
•
"Configuring cascading", page 106
•
"Status indication on both sides", page 108
7.2
Possible combinations of functions on SP2 system plug
Table 30: Possible combinations of functions on SP2 system plug
Function
Be
am c
odin
g
R
es
tar
t int
er
loc
k (In2)
R
es
tar
t int
er
loc
k (In3)
EDM (In1)
EDM (In4)
C
asc
adin
g
Smar
t pr
esenc
e de
tec
tion
Mut
in
g (In1, In2)
Mut
in
g (In2, In4)
P
ar
tial blank
in
g
Smar
t Bo
x D
et
ec
tion
R
educ
ed r
esolut
ion
D
ynamic pr
ot
ec
tiv
e f
ie
ld w
idt
h
Beam coding
–
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Restart interlock at extension
connection (In2)
✓
–
–
✓
✓
✓
✓
–
–
✓
✓
✓
✓
Restart interlock at system
connection (In3)
✓
–
–
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
External device monitoring
(EDM) at extension connec‐
tion (In1)
✓
✓
✓
–
–
✓
✓
–
–
✓
✓
✓
✓
External device monitoring
(EDM) at the system connec‐
tion (In4)
✓
✓
✓
–
–
✓
✓
✓
–
✓
✓
✓
✓
Cascading
✓
✓
✓
✓
✓
–
✓
–
–
–
–
✓
✓
Smart presence detection
✓
✓
✓
✓
✓
✓
–
–
–
–
–
✓
✓
Muting at the extension con‐
nection (In1, In2)
✓
–
✓
–
✓
–
–
–
–
✓
–
✓
✓
Muting at extension connec‐
tion In2 and at system con‐
nection In4
✓
–
✓
–
–
–
–
–
–
✓
–
✓
✓
Partial blanking
✓
✓
✓
✓
✓
–
–
✓
✓
–
–
–
✓
Smart Box Detection
✓
1)
✓
✓
✓
✓
–
–
–
–
–
–
✓
✓
Reduced resolution
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
✓
–
✓
Dynamic protective field
width
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
–
✓
Functions can be combined with each other.
–
Functions cannot be combined with each other.
1)
Smart Box Detection and beam coding (code 1 and code 2) can be combined up to a maximum protective field height of 1,650 mm.
7.3
Factory settings
Table 31: Configurable functions when delivered
Function
Configuration when delivered
Beam coding.
Uncoded
CONFIGURATION
7
8021645/1EB0/2022-04-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTec4
93