Prerequisites
•
SP2 system plug
Configuring the scanning range
The scanning range of the safety light curtain is configured using DIP switches 1 and 2
(row B) on the system plug of the receiver.
The scanning range configuration is taken on by all guest devices in a cascade.
OFF
uncoded
code 1
code 2
rev.conf.
ON
1 2 3 4
O F F
1 2
3 4
O F F
1 2 3 4
O F F
1
O
N
2
A
B
C
D
1 2
3 4
O F F
Figure 59: DIP switches for scanning ranges on SP2 system plug
Table 35: DIP switches and scanning range
DIP switch 1 (row B)
DIP switch 2 (row B)
Function
Off
Off
Automatic calibration of the
protective field width (delivery
condition)
Off
On
Dynamic protective field width
(small range)
On
Off
Dynamic protective field width
(medium range)
On
On
Dynamic protective field width
(large range)
Note on configuration
b
Check the parity after setting the DIP switch,
see "Checking the parity", page 102
.
7.8
Configuring reduced resolution
Important information
NOTE
Reduced resolution is only configured on the receiver of a single or host system.
Prerequisites
•
SP2 system plug
CONFIGURATION
7
8021645/1EB0/2022-04-28 | SICK