Technical data
58
© SICK AG • Subject to change without notice • 8014868/YIF1/2020-10-19
13.2 Laser/optics
Light sender
• Dx35-Bxx2xx, Dx35-Bxx5xx: laser diode, red light
• Dx35-Bxx8xx: laser diode, infrared light
Laser class
• Dx35-Bxx2xx: 2 according to EN 60825-1
• Dx35-Bxx5xx, Dx35-Bxx8xx: 1 according to EN 60825-1
Maximum output
•
Dx35-Bxx2xx, DT35-Bxx5xx, DS35-Bxx5xx: ≤ 250 mW
•
Dx35-Bxx8xx: ≤ 130 mW
•
DL35-Bxx5xx, DR35-Bxx5xx: ≤ 120 mW
Pulse duration
• Dx35-Bxx2xx, Dx35-Bxx5xx: 4 ns
• Dx35-Bxx8xx: 3.5 ns
Shaft Length
• Dx35-Bxx2xx, Dx35-Bx5xx: 658 nm
• Dx35-Bxx8xx: 827 nm
Pulse rate
• Dx35-Bxx2xx, Dx35-Bxx8xx, DL35-Bxx5xx, DR35-Bxx5xx: 1/250
• DT35-Bxx5xx, DS35-Bxx5xx: 1/500
Typical light spot size
15 mm x 15 mm for 2 m distance
Laser operating life (MTTF at +25°C)
100,000 h
Table 22: Laser/optics
13.3 Performance data
Measuring range
DT35-Bxxxxx, DS35-Bxxxxx
1)
• 90 % remission: 50 mm ... 12,000 mm
• 18% remission: 50 mm ... 5,300 mm
• 6% remission: 50 mm ... 3,100 mm
DL35-Bxxxxx, DR35-Bxxxxx
• 200 mm ... 35,000 mm (diamond grade)
→
For “Repeatability” diagrams, see Chapter 13.10 on page 61
Resolution
0.1 mm
Repeatability
2)
0.5 mm … 5 mm
→
For “Repeatability” diagrams, see Chapter 13.10 on page 61
Accuracy
3)
• DT35-Bxxxxx, DS35-Bxxxxx: typically ± 10 mm
• DL35-Bxxxxx, DR35-Bxxxxx: typically ± 15 mm
Output rate
4), 5)
→
Response time
4), 6)
→
Switching frequency
4), 6)
→
Initialization time
≤ 500 ms
Warm-up time
≤ 20 min
1) With the "Super-slow" speed setting
2)
Equivalent to 1 σ