IO-Link interface
48
© SICK AG • Subject to change without notice • 8014868/YIF1/2020-10-19
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
104 (0x68) Alarm function
(bit 0)
UINT8
R/W
•
0: Clamp (zero-val
-
ue output)
• 1: Hold
Select behavior for the
sensor if no measure-
ment is possible.
• Clamp: The sensor
outputs "0".
• Hold: The last valid
measured value is
retained.
Note:
Do not set "hold"
option for ObSB mode.
→
See Chapter 10.4
82 (0x52)
Key lock
UINT8
R/W
•
0: OFF
• 1: ON
0
68 (0x44)
Laser on/off
UINT8
R/W
• 0: OFF
•
1: ON
1
–
Table 17:
SICK-specific service data – other settings
9.3.7
System command
Index
decimal
(hex)
Description
Format
Access
Value
Remarks
2 (0x02)
System command:
Reset to factory
setting
UINT8
W
130
Reset parameter to the factory setting.
Table 18: System command
9.4
Error codes
→
For error codes, see IO-Link specification