8014868/YIF1/2020-10-19 • © SICK AG • Subject to change without notice 35
Commissioning
Performing fine teach (continued)
3. Perform one of the following steps:
• Every time you press the
set (+)
pushbutton, you move the previous-
ly taught-in point by +10 mm.
• Every time you press the
set (–)
pushbutton, you move the previous-
ly taught-in point by –10 mm.
4.
In order to leave fine teach mode, either press the
select
and
set
pushbuttons longer than 1 second or wait 30 seconds without pushing
the pushbuttons.
8.4
Configuring the speed
NOTE!
The configured speed affects the measuring range,
repeatability, switching frequency, and response time to
be achieved.
→
For “Repeatability” diagrams, see Chapter 13.10 on
→
For output rates, response time and switching fre-
quency, see Chapter 13.3 on page 58
1. Press the
select
pushbutton for longer than 5 seconds. The LED
Q1
near
lights up.
2. Keep pressing the
select
pushbutton until the LED
slow … fast
flash
-
es.
3. Keep pressing the
set
pushbutton until the desired speed has been
set.
• LED
slow … fast
flashes cyclically 1 x: super-slow
• LED
slow … fast
flashes cyclically 2 x: slow
• LED
slow … fast
flashes cyclically 3 x: medium
• LED
slow … fast
flashes cyclically 4 x: fast
• LED
slow … fast
flashes cyclically 5 x: super-fast
• LED
slow … fast
lights up continuously: Expert setting, adjustable
only via IO-Link
→
See Chapter 9.3.3 on page 43
4. In order to leave teach mode, either press the
select
pushbutton
longer than 5 seconds or wait 5 minutes without pushing the pushbut-
tons.