Mounting
24
© SICK AG • Subject to change without notice • 8014868/YIF1/2020-10-19
5.
Perform fine adjustment. Align the distance sensor such that the
highest possible alignment quality is indicated. The alignment quality is
indicated as follows:
• using the vertically arranged LEDs Q1 near to slow … fast: The great-
er the number of that LEDs light up, the higher the alignment quality.
•
using the LEDs Q1 and Q2: The faster both LEDs flash, the higher
the alignment quality. Slow flashing at approx. 1 Hz corresponds to
poor alignment quality (no reflective tape). Rapid flashing at approx.
15 Hz corresponds to high alignment quality (highest reflective
level).
6. In order to leave alignment mode, either press the
set
pushbutton
longer than 5 seconds or wait 5 minutes without pushing the pushbut-
tons.
7.
Remove the small reflective tape for alignment from the object.
8.
For DL35 and DR35 variants, attach a large reflective tape for perform
-
ing the measurement.
Q1 Q2
Q1 near
Q1 far
Q2 near
Q2 far
ObSB
select
set
run
ObSB
fast
slow
set
> 5 s
Q1 Q2
Q1 near
Q1 far
Q2 near
Q2 far
ObSB
run
ObSB
fast
slow
Q1 Q2
Q1 near
Q1 far
Q2 near
Q2 far
ObSB
run
ObSB
fast
slow
1 Hz
15 Hz
Fig. 7: Aligning infrared light models, entering alignment mode