8014868/YIF1/2020-10-19 • © SICK AG • Subject to change without notice 41
IO-Link interface
9.3
Service data
9.3.1
IO-Link-specific
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
12 (0x0C)
Device Access
Locks
Record
R/W
16 bytes
–
Only devices from date
code
2034
xxxx and
with IO-Link V1.1
Bit 0: Parameter (write)
access lock
Bit 1: Data storage lock
Bit 2: Local parameter-
ization lock
Bit 3: Local user inter-
face lock
16 (0x10)
Manufacturer
name
String
R
64 bytes
SICK AG
→
See IO-Link specifi
-
cation
17 (0x11)
Manufacturer text
String
R
64 bytes
SICK sensors
–
18 (0x12)
Product name
String
R
64 bytes
DT35-B15251
–
19 (0x13)
Product ID
String
R
64 bytes
1057652
–
21 (0x15)
Serial number
String
R
16 bytes
12130005
–
24 (0x18)
Application-specif-
ic name
String
R/W
IO-Link V1.0: 64 byte
IO-Link V1.1: 32 byte
Dx35 product
family
–
Table 13:
IO-Link-specific service data
Other settings
Index
decimal
(hex)
Description
Format
Access
Value range
Example
Remarks
84 (0x54)
User brand 1
UINT32
R/W
32 bit
–
85 (0x55)
User brand 2
UINT16
R/W
16 bit
–
40 (0x28)
Process data
UINT16
R
16 bit
Content depends on
"process data" setting
Table 14:
IO-Link-specific service data – other settings
9.3.2
SICK-specific – outputs
NOTE!
In the following tables, the factory settings are indicated
in bold in the "Value range" and "Example" columns.