8014868/YIF1/2020-10-19 • © SICK AG • Subject to change without notice 59
Technical data
3) DT35-Bxxxxx, DS35-Bxxxxx: At 6% … 90% remission
DL35-Bxxxxx, DR35-Bxxxxx: on “diamond grade” reflective tape
4)
Depends on the configured speed "super-slow" … "super-fast"
5) Continuous change of the distance from the object in the measuring range
6) Lateral entry of the object into the measuring range
Table 23: Performance data
Output rate, response time, and switching frequency as a function of the speed setting
All Dx35 except for DT35-B15551 and DS35-B15521
Super-fast
Fast
Medium
Slow
Super-slow
Output rate
1 ms
2 ms
4 ms
8 ms
32 ms
Response time
2.5 ms
6.5 ms
12.5 ms
24.5 ms
96.5 ms
Switching frequen-
cy
333 Hz
100 Hz
50 Hz
25 Hz
6 Hz
DT35-B15551 and DS35-B15521
Super-fast
Fast
Medium
Slow
Super-slow
Output rate
2 ms
4 ms
8 ms
16 ms
64 ms
Response time
4.5 ms
12.5 ms
24.5 ms
48.5 ms
192.5 ms
Switching frequen-
cy
166 Hz
50 Hz
25 Hz
12 Hz
3 Hz
Table 24: Overview of output rate, response time, and switching frequency
13.4 Supply
Supply voltage U
V
1)
• 12 V DC … 30 V DC
• 18 V DC … 30 V DC (when using IO-Link)
• DT35-Bxxxxx, DL-Bxxxxx: 13 V DC ... 30 V DC
(when using the analog voltage output)
Power consumption
2)
≤ 1.7 W
Residual ripple
3)
< 5 V
SS
1) Limit values, reverse-polarity protected operation in short-circuit protected network: max. 8 A
2) At 20 °C and without load
3) May not fall short of or exceed U
v
tolerances
Table 25: Supply