2.1.3
Conditions for devices with heating
When using heated devices, you must also keep in mind the following points:
■
Use cables suitable for the ambient conditions. When in doubt, please consult
SICK Service.
■
Supply voltage range restricted: 18
V
DC ... 30
V
DC
■
Connection work only in the temperature range: ‒25°
C ... +40
°C
■
When mounting, make sure that a thermal transition between the device and the
environment is largely reduced. To do this, insert the decoupling material supplied
with the device between the device and the bracket. If necessary, use appropriate
brackets (optional accessories).
■
The device must be in a non-operating state (no mounting or connection work).
2.1.4
Using the USB interface
Device variants with USB interface
NOTE
The USB interface of the device is used in industrial environments only as a service
interface for temporary use (e.g. for configuration, troubleshooting). Permanent use in
operational use of the system as a host interface is not intended.
2.2
Improper use
Any use that goes beyond the areas specified below is considered improper use. This
applies to use outside the technical specifications and the specifications for intended
use.
•
The device does not constitute a safety component in accordance with the respec‐
tive applicable safety standards for machines.
•
The device must not be used in explosion-hazardous or corrosive areas or under
extreme ambient conditions.
•
Only the device variants with heating (CLV61x-Dxxx
F0
) may be operated in the
ambient temperature range below 0
°C.
•
The device variant with heating must not be used in forklift applications in low
temperature conditions.
•
The use of accessories not approved by SICK AG is at your own risk.
WARNING
Danger due to improper use!
Any improper use can result in dangerous situations.
Therefore, observe the following information:
■
Product should be used only in accordance with its intended use.
■
All information in these operating instructions must be strictly observed.
■
Shut down the product immediately in case of damage.
2.3
Cybersecurity
To protect against cybersecurity threats, it is necessary to continuously monitor and
maintain a comprehensive and holistic cybersecurity concept. A suitable concept com‐
prises organizational, technical, procedural, electronic, and physical levels of defense
and provides suitable measures for different types of risks. SICK's products and solu‐
tions must be viewed as a component of this concept.
Information on Cybersecurity can be found at:
SAFETY INFORMATION
2
8017842/19XD/2021-11-19 | SICK
O P E R A T I N G I N S T R U C T I O N S | CLV61x DualPort (PROFINET)
9
Subject to change without notice