Cloning function: storage of the currently valid parameter set
Automated additional storage of the current parameter set with the configuration
data of the device on an external storage medium that is quickly accessible
to the user. The procedure is carried out as part of the recommended backup
concept for the parameter sets of the device. The externally stored parameter set
is also updated automatically each time the currently valid configuration data is
permanently saved.
°
The cloning function provides the basis for performing the following tasks,
for example:
•
Manually transferring an identical parameter set to multiple devices of
the same type on the PROFINET network (cloning). When doing so, the
PN name of each device must be manually configured by the user in
coordination with the PROFINET controller.
•
In the event of a device fault, a convenient and rapid manual transfer of
the currently valid parameter set to an exchange unit of the same type in
the read station.
NOTE
Use an empty memory card to save a parameter set or read diagnostic data for the first
time.
b
To do this, check the contents of the current card on the computer using a card
reader. Delete existing content if necessary.
Device access to the memory card
:
NOTE
The device does not indicate direct access (read, write) to the memory card.
When saving the parameter set, the Sensor LED indirectly indicates when the save
process has completed:
•
When the device starts saving, the sensor LED in the “
Device Ready
” indicator
function goes out.
•
When the device has finished saving, the sensor LED in the “
Device Ready
”
indicator function LED lights up blue again.
NOTICE
Possible data loss!
b
Do not remove the memory card or switch off the supply voltage as long as
the following initiated operation is still being executed on the device using the
SOPAS ET configuration software:
■
Permanent change to the parameter set when saving using the “permanent”
option.
Inserting the memory card in the device:
NOTICE
Risk of damage to the memory card
b
To safely install or uninstall the memory card, insert or remove the card only
when the device is
de-energized
. To do this, disconnect the device from the supply
voltage beforehand.