CLV 41x Bar Code Scanner
© SICK AG • Auto Ident • Germany • All rights reserved
9
Operating Instructions
8 008 224/I982/08-00
Parameter
Value
COM port
freely selectable
Baud rate
9600 bit/s
Data bits
8
Parity
none
Stop bit
1
Table 4
Ø
Copy the operating and parametrization software CLV Setup and the online help
CLV Setup Help to the hard disk of the PC and install the software accordingly
Ø
Set the communication parameters in CLV Setup for port COM x (S
ERIAL
P
ORT
under
O
PTIONS
) as shown in
Table 4
(default setting of the CLV)
With the CLV pulse mode “Sensor Input“, the reading pulse can be triggered with the
Clock button on the programming adapter. For this purpose, choose the pulse mode
via the E
DIT
R
EADING
P
ULSE
field on the D
EVICE
C
ONFIGURATION
card of the user interface
and download it to the CLV.
8. 5 Connecting the interfaces
All of the interfaces are routed via the 15-pin D Sub HD connector
À
(
Table 3
).
8. 5. 1 Connecting the host interface
The CLV is equipped with two host interfaces (RS 232 and RS 422/485). One of
these must be selected for data communication with the host/PC. If the RS 232
interface is not connected to the host, it can be used exclusively to monitor data
traffic on the parallel RS 422/482 interface.
TIP:
The internal modules of the CLV may be damaged irreparably if the data interface
is connected incorreclty.
Ø
Connect the host interface of the CLV to the host in accordance with the EMC
requirements using shielded cables(
Fig. 4
)
Ø
To prevent interference, do not lay the data cables over a long distance parallel
to the power supply and motor cables, e.g. in cable ducts
Ø
Apply the shield on one side (SICK recommendation)
Recommended max. cable lengths between the CLV and host:
CAUTION
Interface type
Transmission rate
Distance from host
RS 232
up to 19 200 bits/s
max. 10 m
38 400 ... 57 600 bits/s
max. 3 m
RS 422/485
1)
max. 38 400 bits/s
max. 1 200 m
max. 57 600 bits/s
max. 500 m
1) with appropriate line termination
Table 5