CLV 41x Bar Code Scanner
© SICK AG • Auto Ident • Germany • All rights reserved
13
Operating Instructions
8 008 224/I982/08-00
The function assignment, pulse duration and polarity of the signals can be modified
via the E
DIT
R
ESULT
O
UTPUTS
field on the D
EVICE
C
ONFIGURATION
card of the user interface.
The Result LED is not affected by this and lights up in Reading mode for a Good
Read until the end of the next reading pulse.
TIP:
Result 1 to Result 3 switching outputs
Switching
PNP-switching to supply voltage V
S
characteristics
Properties
short-circuit + temperature-protected, not electrically isolated from V
S
Function assignment
Result 1: Device Ready, polarity: not inverted
(default setting)
Result 2: Good Read, polarity: not inverted
Result 3: No Read, polarity: not inverted
Pulse duration: 100 ms
Electrical values
0 V
≤
V
Out
≤
V
S
Guaranteed:
V
Out
≤
V
S
−
1.5 V at I
Out
≤
600 mA
I
Out
≤
600 mA
Table 9
9. 1 Securing the CLV
The two fastening threads (
2
,
Fig. 1
) on the bottom, narrow side of the housing are
used to secure the CLV. The thread dimensions are shown in Section
18. Dimensioned
diagrams
.
9. Assembly
Mounting accessories
The CLV can be easily secured to the base to suit the relevant application using one
of the two optional mounting brackets (
Fig. 8
). This facilitates precise adjustment in
two planes. The dimensions of these brackets are shown in Section
18.
Dimensioned drawings
. The elongated holes in the brackets allow the CLV to be
adjusted with a freedom of rotation of approx. ± 15°.
Risk of damage to the housing
The max. depth of engagement of the two M 4 tapped blind holes is 6 mm from
the housing surface. Do not exceed this depth.
Fig. 8. Mounting example: securing the CLV using the mounting bracket (accessory)
Aligning the CLV with the bar code
The alignment between the CLV and line or raster scanner depends on the
application. The basic alignment between the two scanning methods and the
conveyor object is shown in
Fig. 9
.
Mounting bracket (small)
no. 2 020 077
CAUTION