Operating Instructions
8 008 224/I982/08-00
CLV 41x Bar Code Scanner
The CLV 41x with fixed focus is used to detect and decode bar codes in a
stationary reading station automatically, e.g. on objects on a conveyor belt. For this
purpose, it must be mounted securely on the station and supplied with an operating
voltage of 4.5...30 V DC to IEC 742. The CLV outputs the read result via its host
inteface to a higher-level computer for further processing.
1. Intended use
The CLV 41x is supplied with the following:
•
two polling reflectors for automatic reading pulse generation
•
a note on device (yellow) with power connection diagram
•
an additional set of laser warning labels (Class 2) in German and French
One or more of the following, depending on the number of devices ordered:
•
CLV 41x Operating Instructions, in German and English
•
a CD-ROM with the CLV Setup program for Windows™, the online CLV Setup Help
(HTML) software and the browser Iview™
•
a fold-out card with 12 printed profile bar codes
2. Scope of delivery
The following are required to set up and operate the CLV:
•
a SICK AM
V
40-011 Connection Module (no. 1 017 132) or AM
S
40-013
(no. 1 017 135)
Alternatively, an external power supply unit with an output voltage of 4.5 ... 30 V DC
to IEC 742 (functional extra-low voltage) and min. 3 W power output
•
a PC with Windows-based GUI (Windows 3.1™, Windows 95™ or Windows NT™)
and serial port (COM x)
•
an HTML browser (e.g. Netscape™) to use the online help
•
an RS 232 data connection cable (e.g. no. 2 020 319).
Alternatively, the programming adapter for the LCV 410 (order no. available on
request) to connect the PC between the CLV 410 and AMV/AMS 40 as well as an
RS 232 data connection cable (e.g. no. 2 014 054) from the programming adapter
to the PC
•
a 24 V DC ±20% operating voltage for the AM
V
40 or 230 V AC (115V) ±10% for
the AM
S
40
•
a suitable sensor, e.g. a photoelectric switch, if the reading pulse is to be supplied
externally via the switching input on the CLV
3. System requirements
4. Laser protection
Laser radiation!
The radiation emitted by the laser diode (red or IR light) on the CLV 410 is harmful to
the human eye. For this reason, do not look directly into the laser beam.
Opening the housing while the device is in operation does not prevent the laser diode
from being activated by the reading pulse.
The maximum output power of the laser beam at the reading window is 1 . 2 mW.
The CLV, therefore, is assigned to protection class 2.
Laser radiation, do not stare into the beam, class 2 laser product.
Max. output radiation: 1 . 2 mW (223
µµµµµ
s), emitted wavelength: 670 nm
See
Section 15
for further safety instructions!
WARNING!