Fig. 1. CLV 41x design
5. Design
The beeper can be assigned a different result indicator function and the beeper
volume changed (default:
low
) by means of the E
DIT
R
ESULT
O
UTPUTS
field on the
D
EVICE
C
ONFIGURATION
card of the operating interface.
In these operating instructions, it is assumed that the beeper is operated
with the default settings.
TIP:
The beeper
6
either provides an acoustic confirmation that a function was executed
successfully or indicates a malfunction. The sound opening is located below the LED
label on the rear, narrow side of the device (
Fig. 1
).
Operating mode/function
Beeper function
Sequence
Reading mode
*)
1. The beeper confirms the start of reading mode when the device is switched on
1. 2 tones
after the wait time for teach-in mode has elapsed
2. The beeper confirms a good read (default setting) and output of the read result 2. 1 tone
Percentage Evaluation
The beeper confirms output of the reading result after every 100 reads
1. 1 tone
AutoSetup
*)
1. The beeper confirms successful read of the presented profile bar code
1. 1 tone
for the start or end of AutoSetup
2. The beeper confirms successful read of the application-specific bar code
2. 1 tone
3. The beeper signals unsuccessful read of the application-specific bar code
3. 3 tones
after approx. 35 seconds
Profile programming
*)
1. The beeper confirms successful read of the presented profile bar code
1. 1 tone
2. The beeper confirms the start of reading mode 10 s after the last profile
2. 2 tones
bar code has been read
Self-test
The beeper signals successful completion of the self-test after power-up
1 . 1 tone
*)
After a laser timeout of 10 minutes (default), the beeper indicates with one long tone that the laser diode has been switched off
and that the reading pulse has been deactivated automatically.
Table 1
6. Beeper function
&
"
§
/
Key:
!
D Sub HD connector, 15-pin
"
Tapped blind hole M 4, depth: 6 mm
§
Reading window
$
Laser warning label
%
Connection cable
&
Sound opening of beeper (covered)
/
Function LEDs
!
$
$
%