CLV 41x Bar Code Scanner
© SICK AG • Auto Ident • Germany • All rights reserved
41
Operating Instructions
8 008 224/I982/08-00
17. Technical data
Type
CLV 410
CLV 412
CLV 414
Version
Line scanner (standard device), option: raster scanner
Light emission
front, option: lateral
Laser diode (wavelength)
Red-light (
λ
= 670 nm)
Life time of laser diode
MTBF 20 000 h
Laser class of device
Class 2 (to DIN EN 60825-1), shutdown after 10 min. (default)
Useful aperture angle
max. 60° (front light emission)/ max. 50° (lateral light emission)
Scanning/decoding frequency
200 ... 800 Hz
Resolution
0.2 ... 1.0 mm
0.1 ... 0.2 mm
02 ... 0.5 mm
Reading range
40 ... 400 mm
45 ... 95 mm
45 ... 320 mm
Raster height (option)
15 mm (8 lines) at 200 mm reading distance (with lateral light emission)
Bar code print contrast (PCS)
≥
60%
Ambient light compatibility
2000 lx (on bar code)
No. of bar codes per scan
1 ... 3
No. of bar codes per reading interval
1)
1 ... 10 (autodiscriminating)
Bar code types
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode
Bar code length
Max. 50 characters (max. 100 characters across all bar codes per scan)
Print ratio
2:1 ... 3:1
No. of multiple reads
1 ... 99
Optical displays
4 x function LEDs
Acoustic read indicator
Beeper, can be deactivated, result/status messages can be assigned.
Reading pulse
Reflector polling/ switching input/ free-running/ software trigger (data interface)
Data interface
RS 232 or RS 422/485, with variable data output format
Data transmission rate
300 ... 57 600 bits/ s
Protocols
SICK standard and SICK network
Physical configurations
Point-to-point, network (bus), daisy chain (pass-through or master/slave)
Function switching inputs
Sensor 1 (reading pulse) and Sensor 2(teach-in match code 1); opto-decoupled,
V
in max
= +30V, internal delay max. 30 ms
Functional switching outputs
3 x OUT (Result 1...3); PNP, I
out max
= 600 mA, variable pulse duration (10 ... 990 ms)
Electrical connection
15-pin D Sub HD connector, cable length 0.9 m
Operating voltage/power consumption
4.5 ... 30 V DC to IEC 742 (listed class II power supply)/ approx. 3 W
Housing
Die-cast zinc
Enclosure rating/protection class
IP 54 (to DIN 40 050)/Class 3 (to VDE 0106)
EMC/vibration/shock-tested
to IEC 801/IEC 68-2-6 test FC/IEC 68-2-27 test EA
Weight
approx. 250 g with connection cable
Operating/storage temperature
0 ... +40 °C/ -20 ... +70 °C
Max. rel. humidity
90%, non-condensing
1) Reading interval: time window for code evaluation generated internally by reading pulse
Table 23