CLV 41x Bar Code Scanner
© SICK AG • Auto Ident • Germany • All rights reserved
11
Operating Instructions
8 008 224/I982/08-00
Ø
Set the trigger source to S
ENSOR
I
NPUT
via the E
DIT
R
EADING
P
ULSE
field on the D
EVICE
C
ONFIGURATION
card of the user interface and download the parameter settings to
the CLV
An external clock pulse is not required for Percentage Evaluation operating mode.
Fig. 5. Connecting the Sensor 1 input to an external reading pulse sensor
Sensor 1 switching input
Switching
Start internal reading interval when input
characteristics
live (active high; default setting)
Properties
opto-decoupled, non-interchangeable
Electrical values
Low:
-1V
≤
V
in
≤
+1 V
High:
-28 V
≤
V
in
≤
-3 V
-0.3 mA
≤
I
in
≤
+0.3 mA
-18 mA
≤
I
in
≤
-1.4 mA
+3 V
≤
V
in
≤
+28 V
+1.4 mA
≤
I
in
≤
+18 mA
Table 7
Sensor 2 switching input
This input is used exclusively to teach in match code 1. The teach-in procedure is
an alternative to entering the match code on the keyboard via the C
ODE
C
OMPARISON
field on the D
EVICE
C
ONFIGURATION
card of the user interface.
In order to teach in the match code, the input is connected briefly to the power
supply via a switch (
Fig. 6
). This can also take place in the Connection Module.
Fig. 6. Connection of Sensor 2 input for teaching in match code 1
Switch
CLV 41x
PNP sensor
DC 24V
6K8
1
14
15
5
Sensor
GND
GND
DC 24V
DC 24V
Sens GND
Sensor 1
1K5
1K5
V
S
= +4.5...+30 V DC
V
S
V
S
V
S
1 5
5
1
1 4
Terminal assignment
AMV 40-011/AMS 40-012 ,-013:
T. 18
T. 14
T. 15
V
S
SENS
SGND
T. 5
GND
CLV 41x
DC 24V
6K8
1
14
15
5
Sensor
GND
GND
DC 24V
DC 24V
Sens GND
1K5
1K5
V
S
Sensor 2
V
S
SensGND
GND
2
Switch S
Electrical values and properties:
as Sensor 1 (see
Table 7
)
Terminal assignment
AMV 40-011/AMS 40-012, -013:
T. 18
T. 2
T. 15
V
S
Sensor 2
SGND
T. 5
GND
V
S
= +4.5...+30 V DC
Note:
Instead of the bridge the “GND-SGND“
Jumper can be set in the AMV/S 40.