CLV 41x Bar Code Scanner
© SICK AG • Auto Ident • Germany • All rights reserved
23
Operating Instructions
8 008 224/I982/08-00
Step
Action
Response from CLV
3
Present the application-specific
a) CLV confirms the good read with an
bar code at the
maximum
acoustic signal and permanently
reading distance in the application
overwrites the corresponding parameters
for up to 10 seconds (see also
in the code configuration.
16. Reading field diagrams
)
It then outputs two consective
acoustic signals and switches to Reading
mode. The Device Ready LED lights up.
b) If the CLV does not detect a bar code
within approx. 35 s (e.g. incorrect reading
distance, poor print quality), three
acoustic signals are output. AutoSetup
is then restarted automatically.
4After the three acoustic signals, adjust
a) As 1 a
the reading distance or skew (scan
b) The CLV cancels AutoSetup automatically
line angle relative to bar code)
after three unsuccessful attempts
5
Cancel AutoSetup prematurely:
CLV cancels Autosetup automatically and
present profile bar code no. 10
switches to Reading mode (two consecutive
again
acoustic signals). The current parameter
set is not modified.
Table 15 (contd)
Step
Action
Response from CLV
1
Call P
ERCENTAGE
E
VALUATION
mode
CLV displays the evaluation results for
from the T
ERMINAL
menu
100 scans.
of the user interface
(see also Section
10.6 Operating
modes/functions
)
2
Present the application-specific
CLV displays the reading quality obtained
bar code again.
at the corresponding distance.
Table 16
Ø
Test read of the bar code taught in with AutoSetup
Prerequisite:
AutoSetup successfully completed
10. 5 Parametrization with the CLV Setup software
10. 5. 1 Installing the user and parametrization software
In order to switch between operating modes and set the parameters manually, you
need the Windows-based CLV Setup software supplied with the device. The pro-
gram runs on Windows 3.11™, Windows 95™ and Windows NT™. The user interface
can also be used when it is not connected to the CLV to configure application-
specific parameter sets (offline mode). The CLV must be connected to the PC,
however, to transfer modified parameter values (download) directly (online mode).
Ø
Copy the CLV Setup and CLV Setup Help software to the hard disk of your PC and
install the programs.
The user interface (
Fig. 16
) is largely self-explanatory. The introduction and online
CLV Setup Help function demonstrate how easy it is to use.
The data displayed on the configuration cards is first stored temporarily to the main
memory of the PC. You can save this data permanently to a configuration file (*.scl)
on the PC using the S
AVE
A
S
command in the F
ILE
menu.