- 36 -
Main Specifications
Pump Unit
Item Code
090860-0341 090860-1041
Model
MP-
Σ
30KN
Ⅱ
MP-
Σ
100KN
Ⅱ
Operable Flow Rate Range
0.050 to 0.500 L/min
0.10 to 1.50 L/min
Display Range of
Instantaneous Flow Rate
0.000 to 0.750 L/min
0.05 to 2.50 L/min
Constant Flow Rate Ranges
0.1 L/min: 0 to 10.0 kPa
0.2 L/min: 0 to 9.0 kPa
0.3 L/min: 0 to 9.0 kPa
0.4 L/min: 0 to 8.0 kPa
0.5 L/min: 0 to 7.0 kPa
0.3 L/min: 2.0 to 35.0 kPa
0.5 L/min: 2.0 to 33.0 kPa
0.7 L/min: 1.0 to 25.0 kPa
1.0 L/min: 1.0 to 22.0 kPa
1.5 L/min: 1.0 to 10.0 kPa
Accuracy of Flow Rate
Within
±
5% of the set flow rate
±
5% (0.3 to 1.5 L/min)
Range of Integrated Flow
Volume Setting (Volume
Timer)
0.00 to 999.99 L
0.0 to 9999.9 L
Display Range of Integrated
Flow Volume
0.00 to 9999.9 L
0.0 to 99999 L
Display Range of Set Time
0.00 to 999.59 (time: minute)
Time Setting / Display
Year/month/day, hour : minute
Built-In Flow Meter
Mass-flow sensor
Pump Type
Double diaphragm type
Material
Pump head: ABS / POM / TPU, diaphragm: EPDM, valve: EPDM, case: PC
Mode
Manual, down timer, volume timer, cycle timer
Display
Liquid crystal display device (with backlighting)
Communications (USB)
Loading and setting by exclusive communications software
Suction / Exhaust Port
Diameter
O.D. 6 mm and 8 mm
(tube used: I.D. 5 mm dia. and 7 mm dia.)
Range of Operating
Temperature / Humidity
0 to 40
°
C 10 to 90% rh (no condensation)
Electric Power Source
Lithium-ion rechargeable battery (sold separately), AA dry batteries (optional),
AC adapter (optional)
Operating Time
(when a lithium-ion
rechargeable battery is used
in a no-load state)
Over 60 hours
Over 48 hours
Operating Time
(when AA alkaline dry cells
are used in a no-load state)
Over 30 hours
Over 24 hours
Dimension
145 W
×
67 D
×
95 H mm
(excluding protrusions, including lithium-ion rechargeable battery)
Weight
0.65 kg (including lithium-ion rechargeable battery)
Accessories
Suction holder for ultra low flow rate (for MP-
Σ
30KN
Ⅱ
only)
*
The above stated operable flow rate range, constant flow rate range, and accuracy of constant flow rate are for 1
atmospheric pressure. It may be short of the stated performance when it is high altitude and low atmospheric pressure.
*
The operating time is the case for at 25
°
C. The life of the battery varies depending on the ambient temp., usage record,
and suction pressure.
*
When the MP-
Σ
30KN
Ⅱ
is used at flow rates lower than 0.1 L/min, the instantaneous flow rate displayed may deviate
momentarily.