Aqua Timer Plus
-
10/34
Tab. 6 – Selection of the operative modalities through the protection code
Display
Operative state / Data visualised
Code
0 0 0 0
Key in the protection code programmed with the function
SC07
Advance
0 0 0 2
Key the code on the display with the keys
Advance
and
Code
Code
S C - -
State of access to the keying in of the programming codes
Advance
S C 0 0
With the key
Advance
the programming code is selected(
0
9
)
Advance
S C 0 9
The code for the programming of the of the operative modality
Program
L L L 1
The number 1 indicates the single column
Advance
L L L 2
The number 2 indicates the duplex column
In the same way,
in all the following tables
where there is the sequence
Program
S C - -
State of access to the keying in of the programming codes
the sequence
Code
0 0 0 0
Key in the protection code programmed with the function
SC07
Advance
0 0 0 2
Key the code on the display with the keys
Advance
and
Code
Code
S C - -
State of access to the keying in of the programming codes
is substituted when there is a different
protection code
.
IMPORTANT !!!
To remove the protection code, set the value
0000
in the function
SC07
.
If the protection code is forgotten, it is no longer possible to enter the programming functions. In case of need,
contact the SIATA technical service.
Pressing the key
Program Mode
after the selection shown in
tab. 5, proceed to the selection of the regeneration start
mode, as shown in tab. 7.
Tab. 7 – Selection of the control modality of the regeneration start
Display
Operative state / Data visualised
Program
L L - 1
Regeneration by time. The LED
TIME
comes on on the panel
Advance
L L - 2
Regeneration by volume. The LED
VOLUME
comes on on the panel
Advance
L L - 3
Mixed regeneration. The LEDs
TIME
and
VOLUME
come on on the panel