Aqua Timer Plus
-
7/34
4 – STATES OF VISUALISATION OF THE DISPLAY
The display, through the key
Advance
, allows the different operative states and/or data to be visualised.
The LEDs
A
or
B
will indicate which to column the data visualised on the display refers.
Tab. 3 – Data visible on the display
Display
Operative state/ Data visualised
Advance
1 2 . 3 0
Local time. The central dot is flashing.
Advance
0 2 . 3 0
Time programmed for the regeneration. The central dot is not flashing.
Advance
d - 3 0
The programmed number of reserve regenerations (remains fixed).
Advance
d d 3 0
The number of regenerations before the salt runs out (is updated).
Advance
- - - -
If no regeneration is in progress, 4 lines appear
1 C 2 5
If a regeneration is in progress, the progression appears.
Advance
5 . 0 0 0
Value of the residual volume.
5 – GENERAL
The installation of the
controller
must be carried out by qualified personnel; the installation procedures must be carried
out when the controller is disconnected from the electricity supply
5.1 –
Packaging and storage
The packaging consists of a cardboard box with a label identifying the product, carrying the following infrormation:
name of producer and PN producer
AT-PLUS2/05
; the
quick reference guide
for the installation and programming
may be found inside.
No particular procedures are necessary for the removal of the controller from the packaging.
The controller must be stored in environments with the following characteristics:
Temperature of b0°C and +55°C;
Relative humidity of between 30 % and 95 %.
5.2 –
Installation
The controller consists of a PVC box with a cover in plexi-glass which may be opened manually, giving access to the
keypad, and of a cover which may be removed by removing two screws and which gives access to the external
connection terminal board.
The box is covered by a certificate with the
IP65
grade of protection,
Aqua Timer Plus
is therefore protected against
infiltration of dust and direct jets of water. This protection is valid when the cover is closed, and the wiring slots are of
the correct size for the cables used and are correctly assembled. If these conditions are not respected, the level of
protection falls to
IP40
, which gives no protection against infiltration of dust and water.
The back of the box is equipped with mechanical details which allow it to be wall-mounted.