Aqua Timer Plus
-
19/34
Program
3 C L
3 C L 0
Management of salt alarm
disabled
Advance
3 C L
3 C L 1
Management of salt alarm
enabled. See par. 6.9
Program
0 d L
0 d L 0
Normal functioning
Advance
0 d L
0 d L 1
Management of the start of the regeneration in the case of inhibit.
See par. 6.12
Program
1 d L
1 d L 0
FLAG not used
Program
2 d L
2 d L 0
FLAG not used
Program
3 d L
3 d L 0
FLAG not used
Program
Fast flashing of the display. The programming is memorised in eeprom.
6.2.5.c – List of codes to be programmed
For the programming and the meaning of the codes see par. 6.3. In this modality the programming of the following
codes is recommended:
Tab. 18 – Table of the codes in one duplex column modality LLL2 – LL–2
Code
Meaning
SC03
Programming of the regeneration cycle ( stop times )
SC04
Programming of the litre counter divider ( prescaler )
SC05
Programming of the duration of the end of cycle impulse and of the litre counter divider of the
dosing pump
SC06
Programming of the volume of resin, of the percentage of reserve and of the exchange capacity
SC01
Programming of the hardness value
SC00
Initialisation of the system
If the flag
0HL
has been programmed with the value
1
to have also the regeneration by time, the recommended
programming varies as follows:
Tab. 19 – Table of the codes in the one duplex column LLL2 – LL–2
Code
Meaning
SC02
Programming of the time of regeneration and of the interval days between two regenerations
SC03
Programming of the regeneration cycle ( stop times )
SC04
Programming of the litre counter divider ( prescaler )
SC05
Programming of the duration of the end of cycle impulse and of the litre counter divider of the
dosing pump
SC06
Programming of the volume of resin, of the percentage of reserve and of the exchange capacity
SC01
Programming of the hardness value
SC00
Initialisation of the system