Shure Incorporated
64/75
Pre-Tested Shure Cables
Shure offers individually-tested cables for Shure conferencing and discussion equipment. The EC 6001 are high-quality, shield-
ed Cat5e cables available various lengths from 0.5 m to 100 m. Made with male-to-male shielded connectors.
Male-to-Male Patch Cables
0.5 m black shielded Cat5e F/UTP cable (shielded RJ45)
EC 6001-0.5
1 m black shielded Cat5e F/UTP cable (shielded RJ45)
EC 6001-01
2 m black shielded Cat5e F/UTP cable (shielded RJ45)
EC 6001-02
3 m black shielded Cat5e F/UTP cable (shielded RJ45)
EC 6001-03
5 m black shielded Cat5e F/UTP cable (shielded RJ45)
EC 6001-05
10 m black shielded Cat5e F/UTP cable (shielded RJ45)
EC 6001-10
20 m black shielded Cat5e F/UTP cable (shielded RJ45)
EC 6001-20
30 m black shielded Cat5e F/UTP cable (shielded RJ45)
EC 6001-30
50 m black shielded Cat5e F/UTP cable (shielded RJ45)
EC 6001-50
100 m black shielded Cat5e F/UTP cable (shielded RJ45)
EC 6001-100
Technical Specifications
Microflex Complete System
The MXC system conforms to ISO 22259, the international standard for conference systems.
Audio performance specifications are measured from the audio input of a conference unit to the headphone output of a confer-
ence unit.
Wiring Details
Connection to Main Power Supply
Blue
Neutral
Brown
Live
Green/Yellow
Earth (Ground)
DCS-LAN Chain
The CCU uses Cat5e, Cat6 or Cat7 F/UTP or U/FTP cables with shielded RJ45 connectors.
EIA 568-B wiring must be used.
Important:
The names of Cat5/6/7 cable type have changed.